A practical reference on stationary phase: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
Reviewed 2026-02-28. Anything still debated is marked as such rather than presented as settled.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
| Property | Value | Notes |
|---|---|---|
| Column particle size | 3–5 µm for conventional HPLC; sub-2 µm for UHPLC | Smaller particles increase backpressure and efficiency. |
| Typical flow rate | 0.5–2.0 mL/min for a 4.6 mm internal diameter column | Flow scales with column diameter and particle size. |
| UV detection wavelength | 190–400 nm | Selection depends on analyte chromophore. |
| Column temperature | 25–40 °C | Temperature affects retention, selectivity, and pressure. |
| Injection volume | 1–20 µL | Larger volumes may distort early-eluting peaks. |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
== External links == Safety MSDS data Mohajer, Fatemeh; Mohammadi Ziarani, Ghodsi (2021). "An Overview of Quantitative and Qualitative Approaches on the Synthesis of Heterocyclic Kojic Acid Scaffolds through the Multi-Component Reactions". Heterocycles. 102 (2). Japan Institute of Heterocyclic Chemistry: 211. doi:10.3987/REV-20-936.
The most common fault associated with malolactic fermentation is its occurrence when it is not desired. This could be for a wine that is meant to be acidic and fruity (such as Riesling) or it could be a wine that was previously thought to have gone through MLF and bottled only to have malolactic fermentation commence in the bottle. The outcome of this "in-bottle" fermentation is often gassy, hazy wine that can be unpalatable to consumers. Improvement in sanitation and control of lactic acid bacteria in the winery can limit the occurrence of these faults. For early Vinho Verde producers, the slight effervesce that came from in-bottle malolactic fermentation was considered a distinguishing trait that consumers enjoyed in the wine. However, wineries had to market the wine in opaque bottles to mask the turbidity and sediment that the "in-bottle MLF" produced. Today, most Vinho Verde producers no longer follow this practice and instead complete malolactic fermentation prior to bottle with the slight sparkle being added by artificial carbonation. While not necessarily a fault, malolactic fermentation does have the potential of making a wine "protein unstable" due to the resulting change in pH which affects the solubility of proteins in wine. For this reason, protein fining and heat stability tests on wine usually take place after malolactic fermentation has run to completion.
== External links == Infracord spectrometer photograph The Grubb-Parsons-NPL cube interferometer Spectroscopy, part 2 by Dudley Williams, page 81 Infrared materials Properties of many salt crystals and useful links. University FTIR lab example Archived 2017-01-10 at the Wayback Machine from the University of Bristol
Sources: en.wikipedia.org
Michael Balint (Hungarian: Bálint Mihály; 3 December 1896 – 31 December 1970) Hungarian Jewish psychoanalyst convert to Christianity who spent most of his adult life in England. He was a proponent of the Object Relations school and author of numerous academic texts and monographs on psychiatry; was attached to the Tavistock Clinic; in 1968 Balint became president of the British Psychoanalytical Society; his wife was noted psychoanalyst and author, Enid Balint, who directed British Psychoanalytical Society (now Institute of Psychoanalysis). A volume of her papers, Before I was I: Psychoanalysis and the Imagination, was published in 1993. Simon Baron-Cohen (b.1958); clinical psychologist ; professor of developmental psychopathology at University of Cambridge; director of the university's Autism Research Centre and a Fellow of Trinity College; was knighted for services to people with autism; was awarded the Medical Research Council (MRC) Millennium Medal; He is the 2026 recipient of the Grawemeyer Award in Psychology. brother of Sacha Baron Cohen Zygmunt Bauman (19 November 1925 – 9 January 2017) highly influential Polish Jewish writer, sociologist and philosopher, writing on postmodern consumerism and liquid modernity.
=== Intellectual disability === Dysfunction of Rho proteins has also been implicated in intellectual disability. Intellectual disability in some cases involves malformation of the dendritic spines, which form the post-synaptic connections between neurons. The misshapen dendritic spines can result from modulation of rho protein signaling. After the cloning of various genes implicated in X-linked intellectual disability, three genes that have effects on Rho signaling were identified, including oligophrenin-1 (a GAP protein that stimulates GTPase activity of Rac1, Cdc42, and RhoA), PAK3 (involved with the effects of Rac and Cdc42 on the actin cytoskeleton) and αPIX (a GEF that helps activate Rac1 and Cdc42). Because of the effect of Rho signaling on the actin cytoskeleton, genetic malfunctions of a rho protein could explain the irregular morphology of neuronal dendrites seen in some cases of intellectual disability.
The structure of chitin was determined by Albert Hofmann in 1929. Hofmann hydrolyzed chitin using a crude preparation of the enzyme chitinase, which he obtained from the snail Helix pomatia. Chitin is a modified polysaccharide that contains nitrogen; it is synthesized from units of N-acetyl-D-glucosamine (to be precise, 2-(acetylamino)-2-deoxy-D-glucose). These units form covalent β-(1→4)-linkages (like the linkages between glucose units forming cellulose). Therefore, chitin may be described as cellulose with one hydroxyl group on each monomer replaced with an acetyl amine group. This allows for increased hydrogen bonding between adjacent polymers, giving the chitin-polymer matrix increased strength. In its pure, unmodified form, chitin is translucent, pliable, resilient, and quite tough. In most arthropods, however, it is often modified, occurring largely as a component of composite materials, such as in sclerotin, a tanned proteinaceous matrix, which forms much of the exoskeleton of insects. Combined with calcium carbonate, as in the shells of crustaceans and molluscs, chitin produces a much stronger composite. This composite material is much harder and stiffer than pure chitin, and is tougher and less brittle than pure calcium carbonate. Another difference between pure and composite forms can be seen by comparing the flexible body wall of a caterpillar (mainly chitin) to the stiff, light elytron of a beetle (containing a large proportion of sclerotin).
The government announces that TikTok is to be banned on electronic devices used by ministers and other employees, amid security concerns relating to the Chinese-owned app's handling of user data. Scientists identify a gene variant that is known to increases the risk of breast and ovarian cancer, and trace it to people with Orkney Island heritage, more specifically those with ancestry on the island of Westray. COVID-19 in the UK: Office for National Statistics data for the week ending 7 March (6 March in Scotland) indicates COVID-19 cases are falling in Scotland, but the picture is uncertain in the rest of the UK. In England, the survey suggests that 1,322,000 tested positive for the virus, equating to 2.36% of the population, or around 1 in 40. 18 March – Peter Murrell resigns as CEO of the Scottish National Party amid a row over party membership. 19 March The UK government launches the Emergency Alerts service, a service to send text alerts to mobile phones in a situation where it is perceived there is an immediate risk to life. The BBC urges its staff to delete the TikTok app from its official devices amid concerns about its security. 20 March – The British government bans far-right Danish activist Rasmus Paludan from entering the United Kingdom over a threat to burn a Quran in Wakefield, West Yorkshire. 21 March Partygate scandal: Former prime minister Boris Johnson publishes a 52-page defence of his actions during the COVID-19 pandemic in which he acknowledges misleading Parliament over the Partygate scandal, but says he did not do so intentionally.
Sources: en.wikipedia.org
The Trinity test was the first nuclear weapon explosion conducted as part of the US Manhattan Project. There were no warnings to residents about the fallout, nor information about shelters or possible evacuations. This was followed in 1946 by tests in the Marshall Islands (Operation Crossroads), as recounted by chemist Harold Carpenter Hodge (1904-1990), toxicologist for the Manhattan Project, in his lecture (1947) as president of the International Association for Dental Research. Hodge's reputation was severely damaged by historian Eileen Welsome's 1999 Pulitzer Prize-winning book The Plutonium Files - America's Secret Medical Experiments in the Cold War. She documents horrific human experiments in which the subjects (including Hodge) were unaware that they were being used as "guinea pigs" to test the safety limits of uranium and plutonium. The experiments on the unidentified subjects were continued by the United States Atomic Energy Commission (AEC) into the 1970s. The abuse of radiation continues to this day. During the Cold War, ethically reprehensible radiation experiments were conducted in the United States on untrained human subjects to determine the detailed effects of radiation on human health. Between 1945 and 1947, 18 people were injected with plutonium by Manhattan Project doctors. In Nashville, pregnant women were given radioactive mixtures. In Cincinnati, about 200 patients were irradiated over a 15-year period. In Chicago, 102 people received injections of strontium and caesium solutions.
== Properties == The down hair of the vicuña used for the production of vicuña wool is, with an average hair diameter of 11–13.5 microns, one of the finest animal hairs. Only shahtoosh, the hair of the Tibetan antelope, is finer, with an average diameter of 8–13 microns. Among animal textile fibers, besides shahtoosh, only the various silks and byssus have a smaller fiber diameter. The surface structure of the fiber has scales as in sheep wool. The scale spacing is between 7 and 14 scale rings per 100 microns. The cell arrangement of the fiber is bilateral in transmission electron microscopy (as also in guanaco hair), while it is disordered in llama and alpaca. In addition, vicuña wool can also be identified by mass spectrometry.
Metoprolol, sold under the brand names Lopressor and Toprol-XL among others, is a medication used to treat angina, high blood pressure and a number of conditions involving an abnormally fast heart rate. It is also used to prevent further heart problems after myocardial infarction and to prevent headaches in those with migraines. It is a beta blocker, specifically a selective competitive β1 receptor blocker, and is taken by mouth or is given intravenously. Common side effects include trouble sleeping, feeling tired, feeling faint, and abdominal discomfort. Large doses may cause serious toxicity. Risk in pregnancy has not been ruled out. It appears to be safe in breastfeeding. The metabolism of metoprolol can vary widely among patients, often as a result of hepatic impairment or CYP2D6 polymorphism. Metoprolol was first made in 1969, patented in 1970, and approved for medical use in 1978. It is on the World Health Organization's List of Essential Medicines. It is available as a generic medication. In 2023, it was the sixth most commonly prescribed medication in the United States, with more than 59 million prescriptions.
== External links == whatisbifidusregularis.org/ – A deconstruction of the terms Bifidus Actiregularis, Bifidus Regularis, Bifidus Digestivum, L. Casei Immunitas and their variants, as well as the marketing strategy, and information about the potential health benefits of live yoghurts. Food-Info.net – How to select a probiotic Type strain of Bifidobacterium animalis at BacDive – the Bacterial Diversity Metadatabase
An alternative picoinjection method involves utilizing the injection reagent as the conductor of an electric field where a voltage applied to the fluid stimulates injection. Such a method also allows for greater control of injection as the voltage applied corresponds to the volume of reagent fluid injected. Droplet-to-droplet contamination is a challenge of many injection methods. To combat this, Doonan et al. developed a multifunctional K-channel, which flows reagent streams opposite the path of the droplet stream. Utilizing an interface between the two channels, injection is achieved similarly to picoinjection, but any bilateral contamination washed away through continuous reagent flow. Contamination is avoided at the expense of potentially wasting precious reagent.
Sources: en.wikipedia.org
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.
UHPLC uses columns with smaller particles and operates at higher pressures than conventional HPLC. These conditions can improve speed, resolution, and sensitivity. Both techniques use the same fundamental separation principles.
Validation shows that a method performs reliably for its intended purpose across a defined range. It assesses accuracy, precision, specificity, linearity, and robustness. Regulated testing often requires documented validation before routine use.
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.